Whirlpool Dryer Error Code F31
Exhaust thermistor failure
The thermistor measuring exhaust air temperature has failed.
What Does Error Code F31 Mean on a Whirlpool Dryer?
Exhaust thermistor failure.
The thermistor measuring exhaust air temperature has failed.
What Causes Error Code F31?
Here are the most common causes in order of frequency. Start with the most likely cause before moving to the next:
- 1 Thermistor open or shorted 70% of cases
- 2 Connector loose 20% of cases
- 3 Heat-damaged wiring 10% of cases
How to Fix Whirlpool Dryer Error Code F31
- 1
Test thermistor
Room temp: ~10k–12k ohms.
🔩 Multimeter - 2
Check connector
Reseat at thermistor.
- 3
Replace thermistor
Located in exhaust duct inside cabinet.
🔩 Whirlpool dryer thermistor ($15–$40)
How to Reset Error Code F31
After repair, unplug 1 minute and restart.
Note: If the error returns after resetting, the underlying issue has not been resolved. Work through the fix steps above.
When to Call a Professional
If new thermistor and error persists, control board thermistor input failed.